Recharge Package (RCH1)

©1995, 1996, Richard B. Winston

Please Register Please Register

Last modified on Wednesday, January 31, 1996 - 6:27:10 PM

Skip forward to Input instructions for the Recharge Package.

The original instructions for the Recharge Package are on pages 7-6 to 7-7 of McDonald and Harbaugh (1988).

Introduction: The Recharge Package is used to set the rates, timing and location or recharge in model.

Recharge as simulated by the recharge package is independent of head and only occurs in one cell in each vertical column of cells. Recharge to several cells in a vertical column, as might occur in artificial recharge, can be simulated with the Well package. The recharge package also can simulate a steady evapotranspiration rate by specifying a negative recharge rate. The recharge rate has units of length/time.

There are three options for specifying which cell in a vertical column receives recharge.

Under options 1 and 2, if a cell which was supposed to receive recharge is inactive, no recharge will occur in that vertical column of cells. If a cell becomes in active because it dries out during a simulation and it was supposed to receive recharge under options 1 or 2, no recharge will occur in that vertical column. This can cause incorrect results.

Go back to Contents


Input Instructions

All input parameters should be right justified.

Go back to Contents

Line 1, Spaces 1-10, Variable = NRCHOP, Integer, Recharge option

Go back to Input instructions for the Recharge Package.

Line 1, Spaces 11-20, Variable = IRCHCB, Integer, cell-by-cell flag and unit number

(You must also set ICBCFL in the Output Control option to print or save cell-by-cell flow terms.) Go back to Input instructions for the Recharge Package.

Lines 2+, Spaces 1-10, Variable = INRECH, Integer

INRECH tells whether or not Lines 3+ should be read. Line 2 is repeated for every stress period.
Go back to Input instructions for the Recharge Package.

Lines 2+, Spaces 11-20, Variable = INIRCH, Integer, Ignored if NRCHOP = 1 or 3

INIRCH tells whether or not Lines 4+ should be read. It is meaningful only if NRCHOP = 2; otherwise it is ignored. Line 2 is repeated for every stress period.
Go back to Input instructions for the Recharge Package.

Lines 3+, Array = RECH(NCOL,NROW) entered using U2DREL

RECH(NCOL,NROW) gives the recharge rates with units of Length/time. Within MODFLOW, it is multiplied by the cell surface area (DELR x DELC) to obtain the volumetric rate.
Lines 3+ are repeated for every stress period in which INRECH>=0.
Go back to Input instructions for the Recharge Package.

Lines 4+, Array = IRCH(NCOL,NROW) entered using U2DINT

This line is used only if NRCHOP = 2. Each number in IRCH(NCOL,NROW) tells which layer will receive recharge for its position.
Lines 3+ are repeated for every stress period in which NRCHOP=2 and INIRCH >0

Go back to Input instructions for the Recharge Package
Go back to Contents